From 910df73e61f9f5fdb2d24766ce4632b0dfc03be4 Mon Sep 17 00:00:00 2001 From: lumc Date: Thu, 6 May 2021 13:29:11 +0300 Subject: ELCCR-1605: update factory reset documentation Change-Id: I138c24f8e27cf69a8d2d895766522865f6d40fc7 --- .../doc/advanced_configurations.xml | 3 ++- .../doc/installation_guide.xml | 17 ++++++----------- .../doc/net_config_options.xml | 4 ++-- 3 files changed, 10 insertions(+), 14 deletions(-) (limited to 'doc') diff --git a/doc/book-enea-edge-getting-started/doc/advanced_configurations.xml b/doc/book-enea-edge-getting-started/doc/advanced_configurations.xml index c596735..3366a43 100644 --- a/doc/book-enea-edge-getting-started/doc/advanced_configurations.xml +++ b/doc/book-enea-edge-getting-started/doc/advanced_configurations.xml @@ -435,7 +435,8 @@ node0.1048576kB = 3 - Run the following command: + Run the following command and change /opt/ems + to the location where the Enea Edge Management application is installed: ./createCertificate.sh ucpemanager <IP_or_domain> \ /opt/ems [<service_username>] diff --git a/doc/book-enea-edge-getting-started/doc/installation_guide.xml b/doc/book-enea-edge-getting-started/doc/installation_guide.xml index 477b5c4..5f17ad1 100644 --- a/doc/book-enea-edge-getting-started/doc/installation_guide.xml +++ b/doc/book-enea-edge-getting-started/doc/installation_guide.xml @@ -614,14 +614,8 @@ Enea_NFV_Access_uCPEManager_<version>-build<build_number>.tar.gz - Heap Configuration: - - - - Please enter the new Maximum Heap Size - [4g]: - - + Heap Configuration: Please enter the new + Maximum Heap Size [4g]: @@ -1207,9 +1201,10 @@ of=/dev/sdb bs=4M conv=fsync Factory reset. Resets the device to its default factory settings. All current configuration - settings are lost. All running VNFs are destroyed. Any installed - custom scripts will be removed and they will need to be - reinstalled. + settings are lost. All running VNFs are destroyed. All uploaded VM + image files are deleted. Any installed custom scripts will be + removed and they will need to be reinstalled. Existing log files + will be kept. Only the vCPE service will be restarted, the device will not be rebooted. No reboot is needed. diff --git a/doc/book-enea-edge-getting-started/doc/net_config_options.xml b/doc/book-enea-edge-getting-started/doc/net_config_options.xml index ff513c9..5f265fb 100644 --- a/doc/book-enea-edge-getting-started/doc/net_config_options.xml +++ b/doc/book-enea-edge-getting-started/doc/net_config_options.xml @@ -678,8 +678,8 @@ - Once-after-startup. The script will always - execute after the system has rebooted, after all device + Once-after-startup. The script will only + execute once after the system has rebooted, after all device configuration processes have completed. -- cgit v1.2.3-54-g00ecf